• Title of article

    Evaluation of a thermal criterion for an engineered barrier system

  • Author/Authors

    Imbert، نويسنده , , C. and Olchitzky، نويسنده , , E. and Lassabatère، نويسنده , , T. and Dangla، نويسنده , , P. and Courtois، نويسنده , , A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    15
  • From page
    269
  • To page
    283
  • Abstract
    The retention curve of French FoCa compacted clay has been determined at 20, 50 and 80 °C. A saline saturated solution has been used to control the suction. The temperature, up to 80 °C, has no influence on the e(Pc) curve. On the other hand, the water content and the liquid saturation degree are lower at 50 or 80 °C than at 20 °C. A model is proposed to take into account the influence of the temperature, in the framework of Biotʹs theory. od to determine the liquid permeability of an unsaturated porous media is proposed. It is based on an analytical solution and on an experimental survey of the transient phase of desorption. This method has been applied to the compacted FoCa clay, at 20 °C. It is easy to implement and efficient. The permeability of FoCa clay has been determined for a large range of suctions.
  • Keywords
    Swelling clay , FoCa clay , Bentonite , Temperature , Modelling , Capillary curves , Relative liquid permeability , analytical solution
  • Journal title
    Engineering Geology
  • Serial Year
    2005
  • Journal title
    Engineering Geology
  • Record number