Title of article
Evaluation of a thermal criterion for an engineered barrier system
Author/Authors
Imbert، نويسنده , , C. and Olchitzky، نويسنده , , E. and Lassabatère، نويسنده , , T. and Dangla، نويسنده , , P. and Courtois، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
15
From page
269
To page
283
Abstract
The retention curve of French FoCa compacted clay has been determined at 20, 50 and 80 °C. A saline saturated solution has been used to control the suction. The temperature, up to 80 °C, has no influence on the e(Pc) curve. On the other hand, the water content and the liquid saturation degree are lower at 50 or 80 °C than at 20 °C. A model is proposed to take into account the influence of the temperature, in the framework of Biotʹs theory.
od to determine the liquid permeability of an unsaturated porous media is proposed. It is based on an analytical solution and on an experimental survey of the transient phase of desorption. This method has been applied to the compacted FoCa clay, at 20 °C. It is easy to implement and efficient. The permeability of FoCa clay has been determined for a large range of suctions.
Keywords
Swelling clay , FoCa clay , Bentonite , Temperature , Modelling , Capillary curves , Relative liquid permeability , analytical solution
Journal title
Engineering Geology
Serial Year
2005
Journal title
Engineering Geology
Record number
2341185
Link To Document