Title of article
SEAFP-2 bounding accident analyses
Author/Authors
Taylor، نويسنده , , N.P. and Cook، نويسنده , , I and Forty، نويسنده , , C.B.A and Han، نويسنده , , W.E and Taylor، نويسنده , , P، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
15
From page
419
To page
433
Abstract
Analyses have been performed of the potential consequences to the public of hypothetical loss-of-coolant accidents in conceptual fusion power plant designs. In order to establish upper bounds to the consequences of such events, a case has been studied in which total loss of all active cooling has been assumed, with no remedial intervention for the duration of the accident sequence. The analyses are based on three conceptual power plant designs, two of them similar to those assumed in the earlier safety and environmental assessment of fusion power (SEAFP) study (Raeder et al., 1995), with updating of assumed structural materials. The three models studied provide a broad range of design options. In all cases the decay-heat driven temperature transients are well below the level at which structural melting would begin. Based on conservative assumptions, mobilisation, release and dose calculations show that potential maximum doses to the public are very far below the levels at which evacuation might be considered.
Keywords
Power plants , Design , accident analysis