    Upgraded bolometer system on JET for improved radiation measurements

  • Author/Authors

    Huber، نويسنده , , A. and McCormick، نويسنده , , K. L. Andrew Chan، نويسنده , , P. and Beaumont، نويسنده , , P. and Dalley، نويسنده , , S. F. Fink IV، نويسنده , , J. G. Fuchs، نويسنده , , J.C. and Fullard، نويسنده , , K. and Fundamenski، نويسنده , , W. and Ingesson، نويسنده , , L.C. and Mast، نويسنده , , F. and Jachmich، نويسنده , , S. and Matthews، نويسنده , , G.F and Mertens، نويسنده , , Ph and Philipps، نويسنده , , V. and Pitts، نويسنده , , R.A. and Sanders، نويسنده , , S. and Zeidner، نويسنده , , W.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    8
  • From page
    1327
  • To page
    1334
  • Abstract
    Two new main-vessel bolometric cameras (KB5) with horizontal and vertical views of the plasma cross-section have been installed on JET, providing a substantial upgrade in capabilities: more viewing chords (24 chords for each camera), higher energy range (up to 8 keV), higher sensitivity (∼6.2 V/W), lower noise and therefore, lower detectable signals (∼2 μW/cm2 at a bandwidth of 200 Hz), higher temporal resolution (∼2 ms). In addition, three new dedicated divertor bolometer cameras (KB3) with 12 lines-of-sight in total, optimised views and technical improvements have replaced the old ones. The combination of KB3 and KB5 systems provides measurements with significantly improved spatial resolution, allowing the divertor and main chamber radiation fractions to be clearly resolved. The sensitivity measured with an in situ electrical method matches very well with that obtained using a light source calibration. The deviation between the two methods is less than 7% and is in the range of the measurement accuracy. The experimentally measured geometric functions closely match those computed using the design values of geometry. Tomographic reconstructions of high density divertor plasmas with ITER-like configuration are presented which clearly demonstrate the capability of the new diagnostic.
  • Keywords
    JET , tomography , Bolometry camera , PLASMA
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2007
  • Journal title
    Fusion Engineering and Design
  • Record number

    2353917