Title of article
Analysis and design of the beryllium tiles for the JET ITER-like wall project
Author/Authors
Thompson، نويسنده , , V. and Krivchenkov، نويسنده , , Y. and Riccardo، نويسنده , , V. and Vizvary، نويسنده , , Z.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
7
From page
1706
To page
1712
Abstract
Work is in progress to completely replace, in 2008/9, the existing JET CFC tiles with a configuration of plasma facing materials consistent with the ITER design. The ITER-like wall (ILW) will be created with a combination of beryllium (Be), tungsten (W), W-coated CFC and Be-coated inconel tiles, with the material depending on the local anticipated heat flux and geometry. Over 4000 tiles will be replaced and the ILW will accommodate additional heating up to at least 50 MW for 10 s. One of the objectives is to maintain or improve the existing CFC tile power handling performance which has been achieved in most cases by hiding bolt holes, optimising tile size and profile and introducing castellations on plasma facing surfaces. This paper describes the generic problems associated with the Be tiles (power handling capacity and disruption induced eddy currents) and illustrates the solution selected for the inner wall guard limiter (IWGL) where the present CFC tiles will be replaced with Be.
Keywords
Beryllium , Hot spot melting , Eddy currents , JET , First wall tiles , Castellations
Journal title
Fusion Engineering and Design
Serial Year
2007
Journal title
Fusion Engineering and Design
Record number
2354071
Link To Document