Title of article
Water leak localization and recovery in Tore Supra
Author/Authors
Martinez، نويسنده , , A. and Samaille، نويسنده , , F. and Chantant، نويسنده , , M. and Hatchressian، نويسنده , , J.C.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
7
From page
1989
To page
1995
Abstract
For almost 20 years at Tore Supra, plasma facing components (PFCs) are actively cooled by a pressurized water primary loop. Tore Supra can be considered as ITER relevant on this particular aspect. During plasma operation, it happened, that unexpected localized power deposits damaged a PFC leading to more or less large water leaks in the vacuum vessel. The improvement of the procedure to localize the leaky circuits, the investigation of technical solutions for minimizing the amount of water from steam condensation in the vacuum vessel and the optimisation of the quality of the draining and the drying of Tore Supra cooling loop circuits are the result of the experience gained during several years by the analysis of the water leak from plasma facing components (PFCs) and their consequences. Different new specific systems designed and installed during this year to fulfil these objectives are described in this paper.
Keywords
Tore Supra , Active cooling , Water leak , Plasma facing components
Journal title
Fusion Engineering and Design
Serial Year
2007
Journal title
Fusion Engineering and Design
Record number
2354183