Title of article
Aqueous corrosion in static capsule tests representing multi-metal assemblies in the hydraulic circuit of Tore Supra
Author/Authors
Lipa، نويسنده , , M. and Blanchet، نويسنده , , Frans J. M. Feron، نويسنده , , D. and Cellier، نويسنده , , F.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
5
From page
1063
To page
1067
Abstract
Tore supra (TS) in vessel components represent a unique combination of metals in the hydraulic circuit. Different materials, e.g. stainless steel, copper alloys, nickel, etc., were joined together by fusion welding, brazing and friction. Since the operation and baking temperature of all in vessel components has been defined to be set at 230 °C/40 bars a special water chemistry of the cooling water loop was suggested in order to prevent eventual water leaks due to corrosion at relative high temperatures and pressures in tubes, bellows, coils and coolant plant ancillary equipments.
ing experiences with water chemistry in Pressurised Water Reactors, an all volatile chemical treatment (AVT) has been defined for the cooling water quality of TS. Since then, a simplified static (no fluid circulation) corrosion test program at relatively high temperature and pressure has been performed using capsule-type samples made of above mentioned multi-metal assemblies.
Keywords
Aqueous corrosion , Static corrosion tests , Cooling water chemistry , Stress corrosion cracking , Multi-metal assemblies
Journal title
Fusion Engineering and Design
Serial Year
2008
Journal title
Fusion Engineering and Design
Record number
2354976
Link To Document