• Title of article

    Thermal load testing of erosion-monitoring beryllium marker tile for the ITER-Like Wall Project at JET

  • Author/Authors

    Hirai، نويسنده , , T. and Linke، نويسنده , , J. and Rubel، نويسنده , , M. and Coad، نويسنده , , J.P. and Likonen، نويسنده , , J. and Lungu، نويسنده , , C.P. and Matthews، نويسنده , , G.F. and Philipps، نويسنده , , V. and Wessel، نويسنده , , E.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    5
  • From page
    1072
  • To page
    1076
  • Abstract
    ITER-Like Wall Project has been launched at JET in order to perform a fully integrated test of plasma-facing materials. During the next major shutdown a full metal wall will be installed: tungsten in the divertor and beryllium in the main chamber. Beryllium erosion is one of key issues to be addressed. Special marker tiles have been designed for this purpose. Test coupons of such markers have been manufactured and examined. The performance test under high power deposition was carried in the electron beam facility JUDITH. The results of material characterization before and after high heat flux loads are presented. The samples survived, without macroscopic damage, power loads of up to 4.5 MW/m2 for 10 s (surface temperature ∼650 °C) and 50 cyclic loads at 3.5 MW/m2 lasting 10 s each (surface temperature ∼600 °C).
  • Keywords
    JET , ITER , Beryllium , Coating , High heat flux
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2008
  • Journal title
    Fusion Engineering and Design
  • Record number