Title of article
A beam profile monitor for IFMIF
Author/Authors
Surrey، نويسنده , , E. and Day، نويسنده , , I.E. and Holmes، نويسنده , , A.J.T. and O’Mullane، نويسنده , , M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
5
From page
1559
To page
1563
Abstract
The power density of each IFMIF deuteron beam precludes the use of interceptive diagnostics for monitoring deviations from uniformity in excess of ±5%, which may cause boiling of the lithium target within 10 μs. A beam monitor with sufficiently fast response time is therefore required to act as diagnostic tool and interlock signal. This paper explores the options available in terms of present capabilities and future developments. Assessment criteria include signal to noise ratio, sensitivity to changes in beam uniformity, response time of the diagnostic (which must be sub-microsecond), radiation hardness and ageing/lifetime response. There is no proven diagnostic capable of meeting all the requirements but promising candidates are identified and further development prospects discussed.
Keywords
IFMIF , Beam diagnostic , Profile monitor
Journal title
Fusion Engineering and Design
Serial Year
2008
Journal title
Fusion Engineering and Design
Record number
2355286