• Title of article

    Fabrication of thick W coatings by atmospheric plasma spraying and their transient high heat loading performance

  • Author/Authors

    Zhou، نويسنده , , Zhangjian and Song، نويسنده , , Shuxiang and Yao، نويسنده , , Weizhi and Pintsuk، نويسنده , , Gerald and Linke، نويسنده , , Jochen and Guo، نويسنده , , Shuangquan and Ge، نويسنده , , Changchun، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    4
  • From page
    1720
  • To page
    1723
  • Abstract
    Both tungsten coatings with or without a W/Cu graded interlayer on an oxygen-free copper substrate were fabricated by atmospheric plasma spraying. High purity argon gas was used for cooling the substrate and preventing the coating from oxidation. The thickness of both coatings is ∼1 mm. XRD and EDS measurements of the coatings show that minimal oxidation occurred during the deposition process. Transient high heat load tests by electron beam with a pulse duration of 5 ms were performed on both coatings. The single pulse loading was applied on the virgin surfaces at several power densities (from 0.22 to 0.9 GW/m2). Although the weight loss of the W/Cu FGM (functionally graded materials) based coating was slightly lower than that of the pure W coating, their transient high heat loading performances were quite similar.
  • Keywords
    Atmospheric plasma spraying , Transient high heat load tests , Tungsten , Plasma facing materials
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2010
  • Journal title
    Fusion Engineering and Design
  • Record number