• Title of article

    Monte Carlo approach to define the refrigerator capacities for JT-60SA

  • Author/Authors

    Wanner، نويسنده , , Manfred and Barabaschi، نويسنده , , Pietro and Lamaison، نويسنده , , Valerie and Michel، نويسنده , , Fréderic and Reynaud، نويسنده , , Pascal B. Roussel، نويسنده , , Pascal، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    3
  • From page
    1511
  • To page
    1513
  • Abstract
    The JT-60SA cryogenic system shall provide refrigeration to keep the superconducting magnets and their structures at 4.4 K, cryo-pumps at 3.7 K, thermal shields at 80–100 K, and deliver a flow of 50 K helium to the current leads. A Monte Carlo method is proposed to determine the capacity contingencies for the refrigeration system. Attributing individual contingencies and distribution probability functions to the design variables allows the different load contributions to be statistically averaged. The total refrigeration contingency is derived for each temperature level from the 95% confidence level of the integrated distribution function.
  • Keywords
    Contingencies , Monte Carlo , JT-60SA , Cryogenics
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2011
  • Journal title
    Fusion Engineering and Design
  • Record number