Title of article
Safety analyses of water cooled components inside the JET thermonuclear fusion tokamak
Author/Authors
D. and Ageladarakis، نويسنده , , P.A. and Webster، نويسنده , , Richard A. and O’Dowd، نويسنده , , N.P. and Papastergiou، نويسنده , , S.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1999
Pages
16
From page
241
To page
256
Abstract
A theoretical model, supported by extensive experimental verification, has been used to examine the transient thermal behaviour of water cooled components, installed in the vessel of the world’s largest fusion tokamak (JET), under normal operational conditions and abnormal scenarios. Relevant freezing and boiling times for a full range of adverse scenarios were determined by the model, while protective actions were prescribed to safeguard the equipment against freezing or boiling risks. A completely automatic safety protection system, based on the results of the model, has been designed and implemented. The system reacted several times during real off-normal events protecting the relevant JET components.
Keywords
Boiling , Plant maintenance , Water-cooled , Risk , JET , Safety , Accident , Freeze-up
Journal title
Fusion Engineering and Design
Serial Year
1999
Journal title
Fusion Engineering and Design
Record number
2365519
Link To Document