• Title of article

    Characterization of hybrid self-powered neutron detector under neutron irradiation

  • Author/Authors

    Nakamichi، نويسنده , , M and Nagao، نويسنده , , Y and Yamamura، نويسنده , , C and Nakazawa، نويسنده , , M and Kawamura، نويسنده , , H، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    5
  • From page
    837
  • To page
    841
  • Abstract
    To evaluate the irradiation behaviour of a blanket mock-up on in-pile functional test, it is necessary to measure the neutron flux change in the in-pile mock-up by a neutron detector, such as the self-powered neutron detector (SPND). With its small-sized emitter, which has high sensitivity and fast response time, SPND is an indispensable tool in order to measure the local neutron flux change. In the case of an in-pile functional test, it is necessary that response time is less than 1s and ratio of SPND output current is more than 0.3 of output current of SPND with Rh emitter. Therefore, a hybrid SPND with high sensitivity and fast response time was developed. This hybrid SPND used a hybrid emitter, i.e. Co cladded Pt-13%Rh.
  • Keywords
    Hybrid self-powered neutron detector , In-pile functional test , Irradiation behaviour , neutron detector , JMTR
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2000
  • Journal title
    Fusion Engineering and Design
  • Record number