• Title of article

    The ground fault detection system for the Tore Supra toroidal pump limiter

  • Author/Authors

    Zunino، نويسنده , , K. and Cara، نويسنده , , P. and Fejoz، نويسنده , , P. and Hourtoule، نويسنده , , J. and Loarer، نويسنده , , T. and Pomaro، نويسنده , , N. and Santagiustina، نويسنده , , A. and Spuig، نويسنده , , P. and Villecroze، نويسنده , , F.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    5
  • From page
    1019
  • To page
    1023
  • Abstract
    The toroidal pump limiter (TPL) of Tore Supra is electrically insulated from the vacuum-vessel, to allow its polarization at a voltage of up to 1 kV. In order to monitor continuously the integrity of the TPL electrical insulation, an electronic diagnostic system called TPL ground fault detection system (GFDS) has been developed. The paper will report on the design and the operation experience of the GFD system and on the evolution of the TPL grounding.
  • Keywords
    Tore Supra , Ground fault , Toroidal pump limiter
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2003
  • Journal title
    Fusion Engineering and Design
  • Record number