• Title of article

    DC and transient current distribution analysis from self-field measurements on ITER PFIS conductor

  • Author/Authors

    Formisano، نويسنده , , A. S. Ilyin، نويسنده , , Yu. and Muzzi، نويسنده , , L. and Martone، نويسنده , , R. and Gislon، نويسنده , , P. and Nijhuis، نويسنده , , A. and Polak، نويسنده , , M. and Sborchia، نويسنده , , C. and Stepanov، نويسنده , , B.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    5
  • From page
    11
  • To page
    15
  • Abstract
    Current reconstruction in cable-in-conduit conductors (CICC) cables is a crucial issue to determine cables performance in working conditions, and must be performed using inverse problem approaches as direct measurement is not feasible. The current distribution has been studied for the ITER Poloidal Field Insert Sample (PFIS) conductor using annular arrays of Hall probes placed in three different locations along the sample during the test campaign at the SULTAN facility. The measurement apparatus is also described in the paper, together with the approach to current reconstruction.
  • Keywords
    ITER PFIS conductor , CICC cables , Current distribution analysis
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2005
  • Journal title
    Fusion Engineering and Design
  • Record number