• Title of article

    Numerical simulation of the combined effects of plasma heating and neutron heating loads on the ITER first wall

  • Author/Authors

    Zhang، نويسنده , , Pengbo and Zhao، نويسنده , , Jijun and Qin، نويسنده , , Ying and Wen، نويسنده , , Bin، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    6
  • From page
    45
  • To page
    50
  • Abstract
    To understand the combined effect of plasma heating and neutron heating loadings, the distributions of temperature, stress, and strain in different two-dimensional first wall panel models under normal ITER operation condition were simulated using finite element method. The maximum temperature occurs at the Be armor, and reaches 461 °C. High thermal stresses (in the range of 80–200 MPa) are found at the interface between the Be armor and the CuCrZr layer. The maximum thermal stress reaches 324 MPa in the SS316L cooling tube (20 mm diameter), exceeding its yield strength and resulting in a maximum strain of about 1.7% at the tube inner surface. These simulation results are useful for the design and operation of ITER.
  • Keywords
    Thermal Stress , Plasma heating , First wall , Neutron heating
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2011
  • Journal title
    Fusion Engineering and Design
  • Record number