• Title of article

    Hotspot temperature calculation and quench analysis on ITER busbar

  • Author/Authors

    Rong، نويسنده , , J. and Huang، نويسنده , , X.Y. and Song، نويسنده , , Y.T. and Wu، نويسنده , , S.T.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    4
  • From page
    2971
  • To page
    2974
  • Abstract
    This paper describes the analysis of ITER feeder busbar, the hotspot temperature of busbar is calculated by classical method in the case of 0%, 50%, 75% and 100% extra copper (copper strands). The quench behavior of busbar is simulated by 1-D Gandalf code, and the MQE (minimum quench energy) is estimated in classical method as initial external heat in Gandalf input file. The temperature and the normal length of conductor are analyzed in the case of 0%, 50% and 100% extra copper and no helium. By hotspot temperature, conductor temperature and normal length are contrasted in different extra copper cases, it is shown that the extra copper play an important role in quench protecting.
  • Keywords
    Hotspot temperature , Normal length , Minimum quench energy
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2014
  • Journal title
    Fusion Engineering and Design
  • Record number

    2370999