• Title of article

    High dynamic range infrared thermography by pixelwise radiometric self calibration

  • Author/Authors

    Ochs، نويسنده , , M. and Schulz، نويسنده , , A. and Bauer، نويسنده , , H.-J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    8
  • From page
    112
  • To page
    119
  • Abstract
    A procedure is described where the response function of each pixel of an InSb detector is determined by radiometric self-calibration. With the present approach no knowledge of the spectral characteristics of the IR system is required to recover a quantity which is linear with the incident irradiance of the object. The inherent detector non-uniformity is corrected on the basis of self-calibrated scaled irradiance. Compared to the standard two-point non-uniformity correction procedure – performed with the detector signal – only two NUC-tables are required for arbitrary integration times. Images obtained at various exposures are fused to a single high dynamic range image. The procedure is validated with synthetic data and its performance is demonstrated by measurements performed with a high resolution InSb FPA.
  • Keywords
    Radiometric self-calibration , InSb , IRFPA processing , Infrared thermography , High dynamic range , Non-uniformity correction (NUC)
  • Journal title
    Infrared Physics & Technology
  • Serial Year
    2010
  • Journal title
    Infrared Physics & Technology
  • Record number