• Title of article

    Quantitative study of the temperature dependence of normal LWIR apparent emissivity

  • Author/Authors

    Riou، نويسنده , , Olivier and Logerais، نويسنده , , Pierre-Olivier and Durastanti، نويسنده , , Jean-Félix Verrier، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    7
  • From page
    244
  • To page
    250
  • Abstract
    In a previous work, a method of measurement of apparent emissivity in situ was implemented. This approach has the decisive advantage of being suitable for any commercial infrared systems. It was tested successfully to characterize the normal LWIR apparent emissivity of an aluminium nitride plate in the temperature range [40–550 °C]. Apparent emissivity exhibits a tight temperature dependence. By using the classical model of apparent emissivity and taking into account the spectral emissivity of aluminium nitride ceramic and the spectral response of the IR sensor, we modelled our apparent emissivity measurement with 5% of accuracy and with dispersion better than 1% within the overall temperature range. The effect on the apparent emissivity of both the detection window and the temperature dependence of the spectral emissivity are highlighted.
  • Keywords
    Quantitative thermography , Apparent emissivity measurement , Normal LWIR apparent emissivity , spectral emissivity
  • Journal title
    Infrared Physics & Technology
  • Serial Year
    2013
  • Journal title
    Infrared Physics & Technology
  • Record number