• Title of article

    Hyperspectral retrieval of phycocyanin in potable water sources using genetic algorithm–partial least squares (GA–PLS) modeling

  • Author/Authors

    Song، نويسنده , , Kaishan and Li، نويسنده , , Lin and Li، نويسنده , , Shuai and Tedesco، نويسنده , , Lenore and Hall، نويسنده , , Bob and Li، نويسنده , , Zuchuan، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    18
  • From page
    368
  • To page
    385
  • Abstract
    Eagle Creek, Morse and Geist reservoirs, drinking water supply sources for the Indianapolis, Indiana, USA metropolitan region, are experiencing nuisance cyanobacterial blooms. Hyperspectral remote sensing has been proven to be an effective tool for phycocyanin (C-PC) concentration retrieval, a proxy pigment unique to cyanobacteria in freshwater ecosystems. An adaptive model based on genetic algorithm and partial least squares (GA–PLS), together with three-band algorithm (TBA) and other band ratio algorithms were applied to hyperspectral data acquired from in situ (ASD spectrometer) and airborne (AISA sensor) platforms. The results indicated that GA–PLS achieved high correlation between measured and estimated C-PC for GR (RMSE = 16.3 μg/L, RMSE% = 18.2; range (R): 2.6–185.1 μg/L), MR (RMSE = 8.7 μg/L, RMSE% = 15.6; R: 3.3–371.0 μg/L) and ECR (RMSE = 19.3 μg/L, RMSE% = 26.4; R: 0.7–245.0 μg/L) for the in situ datasets. TBA also performed well compared to other band ratio algorithms due to its optimal band tuning process and the reduction of backscattering effects through the third band. GA–PLS (GR: RMSE = 24.1 μg/L, RMSE% = 25.2, R: 25.2–185.1 μg/L; MR: RMSE = 15.7 μg/L, RMSE% = 37.4, R: 2.0–135.1 μg/L) and TBA (GR: RMSE = 28.3 μg/L, RMSE% = 30.1; MR: RMSE = 17.7 μg/L, RMSE% = 41.9) methods results in somewhat lower accuracy using AISA imagery data, which is likely due to atmospheric correction or radiometric resolution. GA–PLS (TBA) obtained an RMSE of 24.82 μg/L (35.8 μg/L), and RMSE% of 31.24 (43.5) between measured and estimated C-PC for aggregated datasets. C-PC maps were generated through GA–PLS using AISA imagery data. The C-PC concentration had an average value of 67.31 ± 44.23 μg/L in MR with a large range of concentration, while the GR had a higher average value 103.17 ± 33.45 μg/L.
  • Keywords
    AISA , GA–PLS , Phycocyanin , Hyperspectral , Semi-empirical model , Cyanobacteria
  • Journal title
    International Journal of Applied Earth Observation and Geoinformation
  • Serial Year
    2012
  • Journal title
    International Journal of Applied Earth Observation and Geoinformation
  • Record number

    2379045