Title of article
Steam plume length diagram for direct contact condensation of steam injected into water
Author/Authors
de With، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
12
From page
971
To page
982
Abstract
Direct Contact Condensation (DCC) of steam in water occurs when steam is introduced into water. It is a phenomenon of high importance in many industrial applications. An important feature of the DCC is the length of the steam plume. Correlations for a steam plume length presently available are accurate only for limited conditions. In this paper, a new two-dimensional steam plume length diagram is presented capable of predicting length accurately for a wide range of conditions. The diagram is validated against experiments. Furthermore, corrections necessary to adopt the diagram for steam injection into a water flow are discussed in the paper.
Keywords
Steam plume , Plume length diagram , steam , direct contact condensation
Journal title
International Journal of Heat and Fluid Flow
Serial Year
2009
Journal title
International Journal of Heat and Fluid Flow
Record number
2381776