• Title of article

    Prediction of Mean Drop Size in Pulsed Packed Extraction Columns

  • Author/Authors

    Torab-Mostaedi، Meisam نويسنده Nuclear Fuel Cycle Research School, Nuclear Science and Technology Research Institute, Tehran, Iran , , Safdari، Jaber نويسنده Nuclear Fuel Cycle Research School, Nuclear Science and Technology Research Institute, Tehran, Iran , , Torabi-Hokmabadi، Farzad نويسنده School of Chemical Engineering, University College of Engineering, University of Tehran, Tehran, Iran ,

  • Issue Information
    فصلنامه با شماره پیاپی 0 سال 2011
  • Pages
    9
  • From page
    3
  • To page
    11
  • Abstract
    Sauter mean drop sizes have been measured in a pulsed packed extraction column for two liquid systems with and without mass transfer conditions. The effects of pulsation intensity, phase flow rates, and interfacial tension on drop size have been investigated under a variety of operating conditions. The drop size is influenced mainly by pulsation intensity and interfacial tension. Significant, but weaker, are the effects of continuous and dispersed phase flow rates. A precise correlation is proposed for predicting mean drop size in terms of operating variables, physical properties of the liquid systems and mass transfer direction. Good agreement between prediction and experiments is found for all operating conditions that were investigated.
  • Journal title
    Iranian Journal of Chemical Engineering
  • Serial Year
    2011
  • Journal title
    Iranian Journal of Chemical Engineering
  • Record number

    2385688