Title of article
Effect of strong‑column weak‑beam design provision on the seismic fragility of RC frame buildings
Author/Authors
LANG Dominik نويسنده , Surana Mitesh نويسنده Department of Earthquake Engineering, Indian Institute of Technology Roorkee, Roorkee, India , Singh Yogendra نويسنده Department of Earthquake Engineering, Indian Institute of Technology Roorkee, Roorkee, India
Pages
11
From page
31
To page
41
Abstract
Incremental dynamic analyses are conducted for a suite of low- and mid-rise reinforced-concrete special moment-resisting
frame buildings. Buildings non-conforming and conforming to the strong-column weak-beam (SCWB) design criterion are
considered. These buildings are designed for the two most severe seismic zones in India (i.e., zone IV and zone V) following the provisions of Indian Standards. It is observed that buildings non-conforming to the SCWB design criterion lead to
an undesirable column failure collapse mechanism. Although yielding of columns cannot be avoided, even for buildings
conforming to a SCWB ratio of 1.4, the observed collapse mechanism changes to a beam failure mechanism. This change in
collapse mechanism leads to a significant increase in the building’s global ductility capacity, and thereby in collapse capacity. The fragility analysis study of the considered buildings suggests that considering the SCWB design criterion leads to a
significant reduction in collapse probability, particularly in the case of mid-rise buildings.
Journal title
Astroparticle Physics
Serial Year
2018
Record number
2412387
Link To Document