Title of article
Selective Determination of Acetate Ion Using Nickel Complex of N,Nיי-biphenyl-2,2יי-diylbis[1-(1H-pyrrol-2-yl) ethanimine] as an Ionophore
Author/Authors
Singh Gyanendra نويسنده Department of Chemistry M.M.H.College Ghaziabad 201001 (U.P). India , Yadav Kalash Chandra نويسنده Mewar University Chittorgarh Rajasthan-312901. India
Pages
10
From page
666
To page
675
Abstract
A new acetate selective poly (vinyl chloride) membrane sensor based on newly
synthesized nickel complex of Schiff base, N,Nʹ-benzene-1,2-diylbis[1-(1H-pyrrol-2-
yl)ethanimine] as an ionophore was prepared. The electrode show Nernstian slope of 31.4±1
mV/decade with improved linear range of 1.6×10-7 to 1.0×10-2 M, with a lower detection
limit of 1.0×10-7 M between pH range of 3.0-9.5, giving a relatively fast response within (5s)
and can be used for at least 2 months without any divergence in potential. The selectivity
coefficient was calculated using matched potential method. The proposed electrode was
successfully applied as an indicator electrode for the titration of arsenate ion with sodium
thiocynide. It was also be used for the determination of arsenate ion in different water
samples
Journal title
Astroparticle Physics
Serial Year
2014
Record number
2412446
Link To Document