Title of article
Validated Spectrophtometric Method for Simultaneous Determination of Buprenorphine and Naloxone in Pharmaceutical Dosage Forms
Author/Authors
Souri, Effat Department of Medicinal Chemistry - Faculty of Pharmacy and Drug Design and Development Research Center - Tehran University of Medical Sciences, Tehran, Iran , Ahmadi, Farzaneh Sadat Department of Pharmaceutical Chemistry - Faculty of Pharmacy Azad University, Tehran, Iran , Barazandeh Tehrani, Maliheh Department of Medicinal Chemistry - Faculty of Pharmacy and Drug Design and Development Research Center - Tehran University of Medical Sciences, Tehran, Iran 2 Ahmadi, Farzaneh Sadat Department of Pharmaceutical Chemistry - Faculty of Pharmacy Azad University, Tehran, Iran , Mohammad Hosseini, Majid Research and Development - Kish Medipharm Company, No. 64, Kish Free Zone Island, Iran , Fadaye Vatan, Sedigheh Research and Development - Kish Medipharm Company, No. 64, Kish Free Zone Island, Iran
Pages
8
From page
112
To page
119
Abstract
Buprenorphine is a partial mu agonist and kappa antagonist which is used for the treatment
of pain and opioid addiction. A mixture of buprenorphine hydrochloride and naloxone
hydrochloride has been approved for the treatment of opioid dependence.
In this study a third order derivative spectrophotometric method based on zero-crossing
technique has been used for the simultaneous determination of buprenorphine hydrochloride
and naloxone hydrochloride in tablets. The measurements were carried out at wavelengths of
257.8 (zero-crossing point of naloxone hydrochloride) and 252.2 nm (zero-crossing point of
buprenorphice hydrochloride) for buprenorphine hydrochloride and naloxone hydrochloride,
respectively in the third order derivative spectra obtained in methanol and 0.1 M NaOH (50:50)
as solvent. The method was found to be linear in the range of 20-80 μg/mL for buprenorphine
hydrochloride and 5-20 μg/mL for naloxone hydrochloride. The within-day and betweenday
coefficient of variation and error values were less than 2.5% and 1.8%, respectively.
The proposed method was successfully used for simultaneous determination of these drugs
in pharmaceutical dosage form without any interference from excipients or need to prior
separation before analysis.
Keywords
Derivative spectrophotometry , Simultaneous , Naloxone hydrochloride , Buprenorphine hydrochloride