Title of article
Increased Rates of Descemet’s Stripping Automated Endothelial Keratoplasty (DSAEK) Graft Failure and Dislocation in Glaucomatous Eyes with Aqueous Shunts
Author/Authors
DeCroos, Francis Char Wills Eye Institute/Mid Atlantic Retina, Philadelphia, PA, USA , DelMonte, Derek W Duke University Eye Center, Durham, NC, USA , Chow, Jessica H Duke University Eye Center, Durham, NC, USA , Stinnett, Sandra S Duke University Eye Center, Durham, NC, USA , Kim, Terry Duke University Eye Center, Durham, NC, USA , Carlson, Alan N Duke University Eye Center, Durham, NC, USA , Afshari, Natalie A Duke University Eye Center, Durham, NC, USA
Pages
11
From page
203
To page
213
Abstract
Purpose: To investigate the rates of Descemet’s stripping automated endothelial
keratoplasty (DSAEK) graft dislocation and failure in glaucomatous eyes, including
eyes with history of trabeculectomy and/or aqueous shunts.
Methods: A retrospective, case-control study on a total of 424 consecutive eyes undergoing
DSAEK at an academic setting compared 96 glaucomatous eyes to a control group of
328 eyes. Pre- and post DSAEK procedure data was aggregated for up to 2 years (mean
follow-up, 6.5±6.9 months) including rates of graft dislocation and failure.
Results: Out of 96 glaucomatous eyes, 20 had undergone trabeculectomy, 27 had
received one or more aqueous shunts, 12 had undergone both procedures and 37 were
on medical therapy. Complete DSAEK graft dislocation and failure occurred in 2.7%
and 3% of non-glaucomatous patients, respectively. Eyes with history of aqueous shunt
surgery experienced graft dislocation and failure rates of 26.0% (OR=4.6, 95% CI 1.5-
13.7, p=0.0067) and 26.0% (OR=10.3, 95% CI 3.8-27.1, p<0.0001), respectively. In contrast,
glaucomatous eyes only on medical therapy (p=0.13) or with history of trabeculectomy
(p>0.40) had no significant increase in graft dislocation or failure rates.
Conclusion: Eyes with medically controlled glaucoma or prior trabeculectomy
demonstrated comparable rates of graft dislocation and failure as compared to controls.
Aqueous shunt surgery was associated with increased rates of graft dislocation and
failure after DSAEK.