• Title of article

    Increased Rates of Descemet’s Stripping Automated Endothelial Keratoplasty (DSAEK) Graft Failure and Dislocation in Glaucomatous Eyes with Aqueous Shunts

  • Author/Authors

    DeCroos, Francis Char Wills Eye Institute/Mid Atlantic Retina, Philadelphia, PA, USA , DelMonte, Derek W Duke University Eye Center, Durham, NC, USA , Chow, Jessica H Duke University Eye Center, Durham, NC, USA , Stinnett, Sandra S Duke University Eye Center, Durham, NC, USA , Kim, Terry Duke University Eye Center, Durham, NC, USA , Carlson, Alan N Duke University Eye Center, Durham, NC, USA , Afshari, Natalie A Duke University Eye Center, Durham, NC, USA

  • Pages
    11
  • From page
    203
  • To page
    213
  • Abstract
    Purpose: To investigate the rates of Descemet’s stripping automated endothelial keratoplasty (DSAEK) graft dislocation and failure in glaucomatous eyes, including eyes with history of trabeculectomy and/or aqueous shunts. Methods: A retrospective, case-control study on a total of 424 consecutive eyes undergoing DSAEK at an academic setting compared 96 glaucomatous eyes to a control group of 328 eyes. Pre- and post DSAEK procedure data was aggregated for up to 2 years (mean follow-up, 6.5±6.9 months) including rates of graft dislocation and failure. Results: Out of 96 glaucomatous eyes, 20 had undergone trabeculectomy, 27 had received one or more aqueous shunts, 12 had undergone both procedures and 37 were on medical therapy. Complete DSAEK graft dislocation and failure occurred in 2.7% and 3% of non-glaucomatous patients, respectively. Eyes with history of aqueous shunt surgery experienced graft dislocation and failure rates of 26.0% (OR=4.6, 95% CI 1.5- 13.7, p=0.0067) and 26.0% (OR=10.3, 95% CI 3.8-27.1, p<0.0001), respectively. In contrast, glaucomatous eyes only on medical therapy (p=0.13) or with history of trabeculectomy (p>0.40) had no significant increase in graft dislocation or failure rates. Conclusion: Eyes with medically controlled glaucoma or prior trabeculectomy demonstrated comparable rates of graft dislocation and failure as compared to controls. Aqueous shunt surgery was associated with increased rates of graft dislocation and failure after DSAEK.
  • Keywords
    Glaucoma , Descemet’s Stripping Endothelial Keratoplasty , Descemet’s Stripping Automated Endothelial Keratoplasty , Aqueous Shunt , Graft Failure , Graft Dislocation
  • Journal title
    Astroparticle Physics
  • Serial Year
    2012
  • Record number