• Title of article

    Reliability of the universal goniometer for assessing active cervical range of motion in asymptomatic healthy persons

  • Author/Authors

    Farooq, Muhammad Nazim University Institute of Physical Therapy - Faculty of Allied Health Sciences , Mohseni Bandpei, Mohammad A. University Institute of Physical Therapy - Faculty of Allied Health Sciences , Ali, Mudassar Margalla Institute of Health Sciences , Ali Khan, Ghazanfar Margalla Institute of Health Sciences

  • Pages
    5
  • From page
    457
  • To page
    461
  • Abstract
    Objective: To determine within-rater and between-rater reliability of the universal goniometer (UG) for measuring active cervical range of motion (ACROM) in asymptomatic healthy subjects. Methods: Nineteen healthy subjects were tested in an identical seated position. Two raters used UG to measure active cervical movements of flexion, extension, right side flexion, left side flexion, right rotation and left rotation. Each motion was measured twice by each of the two raters and was re-measured all over again after one week. Data analysis was performed using the intraclass correlation coefficient (ICC). Results: The results demonstrated excellent within-session (ICC2,1 = 0.83 to 0.98) and between-session (ICC2,2 = 0.79 to 0.97) intra-rater reliability and excellent inter-rater reliability (ICC2,2 = 0.79 to 0.92). Conclusion: Considering above results it is concluded that UG is a reliable tool for assessing ACROM in a clinical setting for healthy subjects.
  • Keywords
    Reliability , Range of motion , Neck , Universal goniometry
  • Journal title
    Astroparticle Physics
  • Serial Year
    2016
  • Record number

    2422895