• Title of article

    Failure of Cone-Beam Computed Tomography in Detection of Fiber Post Perforation

  • Author/Authors

    Fazlyab, Mahta Department of Endodontics - Dental Branch, Islamic Azad University, Tehran , Asgary, Saeed Iranian Center for Endodontic Research - Research Institute of Dental Sciences - Dental School, Shahid Beheshti University of Medical Sciences, Tehran

  • Pages
    5
  • From page
    396
  • To page
    400
  • Abstract
    Detection of iatrogenic root perforation during post-space preparation especially in labiolingual plane can be challenging due to the two-dimensional nature of conventional radiography; this can be even more challenging if the cemented post is radiolucent. Cone-beam computed tomography (CBCT) scans were shown to be a valuable diagnostic aid in diagnosis of such cases. However, in this case, the application of CBCT did not help in diagnosis of a labial fiber post perforation in a maxillary central incisor which was finally detected through exploratory surgery.
  • Keywords
    Calcium-Enriched Mixture , Cone-Beam Computed Tomography , Diagnosis , Post Space Preparation , Root Perforation
  • Journal title
    Astroparticle Physics
  • Serial Year
    2017
  • Record number