• Title of article

    The Effect of Inter-Implant Distance on Retention and Resistance to Dislodging Forces for Mandibular Implant-Tissue-Supported Overdentures

  • Author/Authors

    Tabatabaian, Farhad Department of Prosthodontics - Dental School, Shahid Beheshti University of Medical Sciences, Tehran , Saboury, Abolfazl Department of Prosthodontics - Dental School, Shahid Beheshti University of Medical Sciences, Tehran , Sobhani, Zahra Sadat Dental School of Shahid Beheshti University of Medical Sciences, Tehran , C Petropoulos, Vicki Department of Preventive and Restorative Sciences - University of Pennsylvania School of Dental Medicine, United States

  • Pages
    10
  • From page
    506
  • To page
    515
  • Abstract
    Objectives: The effect of inter-implant distance on retention and resistance of implant- tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments. Materials and Methods: An acrylic cast of an edentulous mandible was fabricated. Three pairs of implants were symmetrically placed at both sides of the midline. The inter-implant distance was 10, 25, and 35 millimeters in positions A, B and C, respectively. A frame- work simulating the overdenture was fabricated on the cast. Six attachment housings were placed within the overdenture. For each sample, two ball abutments were screwed onto the implant pairs and two pink nylon inserts were seated in their respective attachment hous- ings. The samples were tested in three groups of 15 (A, B, and C). The testing machine applied tensile dislodging forces and peak loads were measured in three directions: vertic- al, oblique, and anterior-posterior. A one-way ANOVA followed by Tukey’s HSD was used to determine groups that were significantly different. Tests were carried out at 0.05 level of significance. Results: Peak loads for the anterior-posteriorly directed dislodging forces were signifi- cantly the highest for group C (P<0.05); 21.25 N±3.05 N, while there were no statistically significant differences among groups with vertically and obliquely directed forces (P>0.05). Conclusion: Inter-implant distance did not affect the vertical retention and oblique resistance of mandibular implant-tissue-supported overdentures; however, it affected anterior- posterior resistance
  • Keywords
    Dental Implant , Overdenture , Dental Prosthesis Retention , Implant- Supported Dental Prosthesis
  • Journal title
    Astroparticle Physics
  • Serial Year
    2014
  • Record number

    2425955