    Naderi, Mansoor Department of Energy System Engineering - Petroleum University of Technology - Abadan, Iran , Zargar, Ghasem Department of Energy System Engineering - Petroleum University of Technology - Abadan, Iran , Khalili, Ebrahim National Iranian Gas Company (NIGC) - Shahrekord Gas Company - Shahrekord, Iran

  • Pages
    17
  • From page
    93
  • To page
    109
  • Abstract
    Heat EXchangers (HEX) that are used in City Gate Station (CGS) systems are modeled numerically to recover the exhaust waste heat. It was tried to find the best viscous model to obtain results in accordance with experimental results and to change the heat exchanger design. This HEX is used for recovering heat from exhaust flue gas with a mixture of 40% water and 60% ethylene glycol as the cooling fluid. Then, the effects of sizes and numbers of fins and tube rows on recovered heat rate were investigated under various pump speeds. As the first step in solving the problem, SST k–ω and RNG k–ε suitable viscous models were chosen for these kinds of problems. Secondly, a new HEX is designed at a fixed coolant speed, pipe and fin thickness, and shell dimension because of operational constraints. Finally, the best HEX with the minimum pressure drop (minimum fin number) is numerically analyzed, and the new HEX specifications were extracted.
  • Keywords
    Numerical Study , Heat Recovery Systems , Gas Pressure Reduction Station , Air Cooler Heat Exchanger