Title of article
Experimental Investigation on the Influences of Different Horizontal Fire Locations on Smoke Temperature Stratification under Tunnel Ceiling
Author/Authors
Haddad, R. K Universiti Kebangsaan Malaysia - Malaysia , Zulkifli, R Universiti Kebangsaan Malaysia - Malaysia , Maluk, C The University of Queensland - Australia , Harun, Z Universiti Kebangsaan Malaysia - Malaysia
Pages
10
From page
1289
To page
1298
Abstract
The increased probability of fire occurrence in urban tunnels has led researchers to investigate this issue
extensively. Although fire can occur at any point in a tunnel, the effect of fire source position on temperature
distribution has not received considerable attention in most of previous investigations. In this research, the
influences of varying horizontal fire source locations on temperature diffusion in particular maximum smoke
temperature stratification beneath the ceiling has been investigated. A set of scale-down experiments was
performed in a model tunnel [3 m (length) × 0.6 m (width) × 0.96 m (height)]. n-Heptane and gasoline were
used as fuels in rectangular pools to generate a heat source. The analysis reveals that typical temperature curves
have a similar trend when the fire source location changes. Furthermore, the temperature profile tip (maximum
smoke temperature) is located between the burner and the origin of the tunnel. The modified model of maximum
temperature, which considers the horizontal fire source location, is defined. The results here complement
existing literature where the effects of variable fire position in a tunnel have not been considered
Keywords
Horizontal fire source location , Maximum smoke temperature , Model tunnel
Serial Year
2020