• Title of article

    Radiation Organ Dose Measurement and Cancer Risk Estimation in CT Examination on Trauma Patients

  • Author/Authors

    Vafaei, Ali Hearing Disorders Research Center - Loghman Hakim Hospital - Shahid Beheshti University of Medical Sciences , Khosravi, Nafiseh Skull Base Research Center - Loghman Hakim Hospital - Shahid Beheshti University of Medical Sciences , Shojaei Barjouei, Nazli International Branch - Shahid Beheshti University of Medical Sciences , Gholizadeh Sendani, Neda Department of Medical Radiation Engineering - University of Isfahan , Oloumi Sadeghi, Ali Department of Emergency Medicine - Shahid Beheshti University of Medical Sciences , Shams Akhtari, Amin Department of Emergency Medicine - Shahid Beheshti University of Medical Sciences

  • Pages
    8
  • From page
    206
  • To page
    213
  • Abstract
    Background: This study intended to measure radiation doses to various organs and calculate the risk of cancer incidence from neck computed tomography and head computed tomography scans of trauma patients by using a thermoluminescent dosimeter. Methods:We assessed 93 patients who presented to the Emergency Department. Based on their health conditions, different computed tomography scans were performed. We used a fixed tube current of 200 mAs and tube voltage of 120 kVp for all patients. Next, we derived the effective radiation dose by multiplying the dose length product and conversion factor of each computed tomography scan based on the International Commission on Radiological Protection 103. Organ dose estimations were calculated from the dosimeter readout. We calculated the life attributable risk for cancer incidence based on the Committee on the Biological Effects of Ionizing Radiation VII preferred models. Results: Neck computed tomography scans had a mean effective dose of 2.18 mSv. The mean effective dose for head computed tomography scans was 1.53 mSv. The highest mean equivalent organ dose was for the thyroid with the neck computed tomography scan and the lenses of the eyes with the head computed tomography scan. There was no significant difference between scan lengths in each computed tomography acquisition. There was a noticeable correlation observed between effective radiation dose and tube current. As anticipated, young people had a higher life attributable risk of cancer compared to the elderly. This amount was less than 0.011 per 100 persons for both computed tomography studies. Conclusion: Our data showed a significant organ radiation dose in both neck and head computed tomography scans, not only for the thyroid and the lenses of the eyes, but also for the chest.
  • Keywords
    Radiation dose , Emergency care , Computed tomography , Trauma
  • Journal title
    Middle East Journal of Cancer (MEJC)
  • Serial Year
    2019
  • Record number

    2500815