Title of article
Comparative performance assessment of flat plate and evacuated tube collectors for domestic water heating systems in Kerman, Iran
Author/Authors
Farzan, Hadi Mechanical Engineering Department - Engineering Faculty - Higher Education Complex of Bam - Bam, Iran
Pages
10
From page
143
To page
152
Abstract
This study represents a year-round energy performance of two solar water heating (SWH) systems with a 4m2 flat plate collector (FPC) and an evacuated tube collector (ETC) operating under the same weather conditions. The energy performance of the two considered systems was compared on a monthly and yearly basis. The obtained results showed that for an annual total solar insolation of 2056kW.h.m-2, a total of 3577kW.h.y-1 and 4201kW.h.y-1 of heat energy were collected by 4m2 FPC and, ETC systems, respectively. The annual average energy efficiency by the FPC system was 43%, while its annual solar fraction was 50%. The ETC system had 51% energy efficiency with 58% solar fraction. The economic analysis showed that both solar water heating systems are not economically viable under prevailing costs in Iran. Furthermore, according to the obtained results, the FPCs are more favorable than the ETCs due to its economic analysis and energy performance. These results provide useful information for households and policymakers.
Keywords
Solar Water Heater , Economic Analysis , Energy Performance Analysis , Evacuated Tube Collector , Plat Plate Collector
Journal title
Energy Equipment and Systems
Serial Year
2020
Record number
2536719