Title of article
STIRRED TANK WITH ARROWHEAD IMPELLER - INFLUENCE OF SUBMERGENCE DEPTH ON POWER CONSUMPTION
Author/Authors
Devi, Thiyam Tamphasana Indian Institute of Technology Guwahati - Department of Civil Engineering, India , Malsur, Banoth Indian Institute of Technology Guwahati - Department of Civil Engineering, India , Kumar, Bimlesh Indian Institute of Technology Guwahati - Department of Civil Engineering, India
From page
45
To page
47
Abstract
Impeller submergence governs the performance of mixing tanks employed in chemical and biochemical operations. Present work experimentally investigates the effect of impeller submergence depths on power consumption when arrowhead impeller has been used in the process. Arrowhead impeller performs better than the conventional Rushton impeller. It has been found that at higher range of impeller submergence, mixing processes consume less power. Optimal range of submergence depth is 0.8 to 0.9 times the impeller diameter.
Keywords
arrowhead impeller , mixing tanks , power consumption , rotational speed
Journal title
Chemical Engineering Research Bulletin
Journal title
Chemical Engineering Research Bulletin
Record number
2550995
Link To Document