Title of article
PERFORMANCE ASSESSMENT OF A COGENERATION SYSTEM IN FOOD INDUSTRY
Author/Authors
Özdil, N. F. Department of Engineering - Adana Science and Technology University, Adana, TURKEY , Tantekin, A. Department of Engineering - Adana Science and Technology University, Adana, TURKEY , Pekdur, A. Adana Metropolitan Municipality, Adana, Turkey
Pages
8
From page
1847
To page
1854
Abstract
Extensive analysis of the thermodynamics first and second laws is performed on a 14.25 MW cogeneration plant in Adana, Turkey. In this study, the most important parts of the system is observed and thermodynamic performance assessments are evaluated. The obtained outcomes indicate that major exergy destruction happens in boiler, which is 42% of the whole system irreversibility. Moreover, the economizer and chimney have also considerable irreversibilities which are 29% and 25%, respectively. The energy efficiencies of the chimney, economizer and boiler are calculated as 61.68%, 66.03%, 79.91%, respectively. On the other hand, the exergy efficiencies of chimney, economizer and boiler are calculated as 96.56%, 30.27% and 71.94%, respectively.
Keywords
Cogeneration , Energy , Exergy , Thermodynamic Analysis , Food Industry
Journal title
Journal of Thermal Engineering
Serial Year
2018
Record number
2576322
Link To Document