Title of article
Air embolism through open hub of external jugular vein intravenous cannula
Author/Authors
Mohanty, Chitta R. Department of Trauma & Emergency - AIIMS - Bhubaneswar, India , Ahmad, Suma R. Department of Anaesthesia and Critical Care - AIIMS - Bhubaneswar, India , Jain, Mantu Department of Orthopaedics - AIIMS - Bhubaneswar, India , Sriramka, Bhavna Department of Anaesthesia and Critical Care - IMS & SUM Hospital - Bhubaneswar, India
Pages
3
From page
117
To page
119
Abstract
Venous air embolism is a catastrophic complication that can result in sudden cardiac arrest and death. Massive air embolism has been reported with central venous catheter through the internal jugular and subclavian veins. Though external jugular vein is a potential site of an air embolism to cardiac chambers and subsequently to vital organs such as brain, heart and lungs but has not been reported yet in literature.
Case presentation
We are reporting a case of sudden pulmonary air embolism in a patient through the open hub of an intravenous cannula, vigilant monitoring and timely action saved the patient from a catastrophic outcome.
Conclusion
We recommend vigilant monitoring and adequate precaution in patients with external jugular venous cannulation in the operation theater, intensive care unit or wards to prevent iatrogenic complications.
Keywords
Intravenous cannula , External jugular vein , Air embolism , Vigilance
Journal title