• Title of article

    EFFECT OF ASPECT RATIO AND FILLING RATIO ON THERMAL PERFORMANCE OF AN INCLINED TWO-PHASE CLOSED THERMOSYPHON

  • Author/Authors

    SARMASTI EMAMI, M. R. university of sistan and baluchestan - Dept of Chem Eng, زاهدان, ايران , Noie, S. H. ferdowsi university of mashhad - Faculty of Engineering - Dept of Chem Eng, مشهد, ايران , KHOSHNOODI, M. ferdowsi university of mashhad - Faculty of Engineering - Dept of Chem Eng, مشهد, ايران

  • From page
    39
  • To page
    51
  • Abstract
    In this paper the effect of the aspect ratio and filling ratio on the thermal performance of an inclined two-phase closed thermosyphon under normal operating conditions has been investigated experimentally. The experiments were carried out for filling a ratio range of 20% = F.R= 60% and aspect ratios of 15, 20, and 30 for an inclination angle range of 15°= (phi) = 90°. The thermosyphon was manufactured using a copper tube with an inside and outside diameter of 14 and 16 mm respectively, and a 1000 mm length. Distilled water was used as the working fluid . The heat transfer rate, temperature distribution, and condensation heat transfer coefficient of the inclined two-phase closed thermo syphon were measured . The results showed that the maximum thermal performance of the thermosyphon occurred at 60° for all three aspect ratios and several filling ratios . The thermal performance of the inclined thermo syphon with an inclination angle of 60° was better for a filling ratio of 45%. It was also found that a higher condensation heat transfer coefficient for all three aspect ratios took place between 30 and 45 degrees.
  • Keywords
    Inclined two , phase closed thermosyphon , inclination angle , filling ratio , aspect ratio.
  • Journal title
    Iranian Journal of Science and Technology :Transactions of Electrical Engineering
  • Journal title
    Iranian Journal of Science and Technology :Transactions of Electrical Engineering
  • Record number

    2596265