• Title of article

    DINOSARC: Color Features Based on Selective Aggregation of Chromatic Image Components for Wireless Capsule Endoscopy

  • Author/Authors

    Vasilakakis, Michael D Department of Computer Science and Biomedical Informatics - University of Thessaly - Lamia, Greece , Iakovidis, Dimitris K Department of Computer Science and Biomedical Informatics - University of Thessaly - Lamia, Greece , Spyrou, Evaggelos Department of Computer Science and Biomedical Informatics - University of Thessaly - Lamia, Greece , Koulaouzidis, Anastasios Endoscopy Unit - The Royal Infirmary of Edinburgh - Edinburgh, UK

  • Pages
    11
  • From page
    1
  • To page
    11
  • Abstract
    Wireless Capsule Endoscopy (WCE) is a noninvasive diagnostic technique enabling the inspection of the whole gastrointestinal (GI) tract by capturing and wirelessly transmitting thousands of color images. Proprietary software “stitches” the images into videos for examination by accredited readers. However, the videos produced are of large length and consequently the reading task becomes harder and more prone to human errors. Automating the WCE reading process could contribute in both the reduction of the examination time and the improvement of its diagnostic accuracy. In this paper, we present a novel feature extraction methodology for automated WCE image analysis. It aims at discriminating various kinds of abnormalities from the normal contents of WCE images, in a machine learning-based classification framework. )e extraction of the proposed features involves an unsupervised color-based saliency detection scheme which, unlike current approaches, combines both point and region-level saliency information and the estimation of local and global image color descriptors. )e salient point detection process involves estimation of DIstaNces On Selective Aggregation of chRomatic image Components (DINOSARC). )e descriptors are extracted from superpixels by coevaluating both point and region-level information. )e main conclusions of the experiments performed on a publicly available dataset of WCE images are (a) the proposed salient point detection scheme results in significantly less and more relevant salient points; (b) the proposed descriptors are more discriminative than relevant state-of-the-art descriptors, promising a wider adoption of the proposed approach for computer-aided diagnosis in WCE.
  • Keywords
    Chromatic , Endoscopy , WCE , DINOSARC
  • Journal title
    Computational and Mathematical Methods in Medicine
  • Serial Year
    2018
  • Record number

    2610326