• Title of article

    EXPLORING CORTICAL BONE DENSITY THROUGH THE ULTRASOUND INTEGRATED REFLECTION COEFFICIENT

  • Author/Authors

    Patterson Matusin, Daniel Biomedical Engineering Program - Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia (COPPE) - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil , Fontes-Pereira, alDo José Biomedical Engineering Program - Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia (COPPE) - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil , taDeu CarDozo ribeiro rosa, Paulo Biomedical Engineering Program - Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia (COPPE) - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil , barboza, thiago Biomedical Engineering Program - Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia (COPPE) - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil , augusto loPes De souza, sergio Biomedical Engineering Program - Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia (COPPE) - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil , antônio von Krüger, MarCo Biomedical Engineering Program - Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia (COPPE) - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil , Coelho De albuquerque Pereira, Wagner Biomedical Engineering Program - Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia (COPPE) - Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil

  • Pages
    5
  • From page
    255
  • To page
    259
  • Abstract
    Objective: This work evaluates the relationship between ul- trasonic reflection and bone density from fourteen cylindrical bovine cortical bone samples (3.0-cm thick). Methods: Twenty US reflection signals per sample were acquired along the bone surface (2.0-mm step). The Integrated Reflection Coefficient (IRC) from each signal was compared to Quantitative Com- puted Tomography (QCT). Results: Seven IRC and QCT curves presented Pearson’s Correlation R-values above 0.5. For weak correlation curves, QCT and IRC showed similar trends in several segments. Conclusion: IRC was sensitive to bone density varia- tion. Level of Evidence: Experimental Study, Investigating a Diagnostic Test.
  • Farsi abstract
    فاقد چكيده فارسي
  • Keywords
    Ultrasonics , Cortical bone , Bone and Bones , Tomog- raphy , Bone density
  • Journal title
    Acta Ortopedica Brasileira
  • Serial Year
    2018
  • Record number

    2617056