Title of article
ACCURACY OF PEDICLE SCREW INSERTION: A COMPARISON BETWEEN FLUOROSCOPIC GUIDANCE and NAVIGATION TECHNIQUES
Author/Authors
Pinto de oliveiRa BilhaR, RomeRo Universidade Federal do Ceará - Faculdade de Medicina - Department of Orthopedics and Traumatology, Fortaleza, CE, Brazil , aRiel de lima, diego Universidade Federal do Ceará - Faculdade de Medicina - Department of Orthopedics and Traumatology, Fortaleza, CE, Brazil , alBeRto dias leite, José Universidade Federal do Ceará - Faculdade de Medicina - Department of Orthopedics and Traumatology, Fortaleza, CE, Brazil , aguiaR PoRto, maximiliano Universidade Federal do Ceará - Faculdade de Medicina - Department of Orthopedics and Traumatology, Fortaleza, CE, Brazil
Pages
4
From page
397
To page
400
Abstract
Objectives: To compare the accuracy of insertion of pedicle screws
into the thoracic spine using fluoroscopic guidance or computer-as-
sisted navigation techniques. Methods: Eight cadaveric thoracic
spines were divided into two groups: the fluoroscopy group, in which
pedicle screws were inserted with the guidance of a C-arm device, and
the navigation group, in which insertion of the screws was monitored
using computer-assisted navigation equipment. All procedures were
performed by the same spinal surgeon. The rate of pedicle breach
was compared between the two groups. Results: There was one
intra-canal perforation in each group. Both perforations were medial
in direction, and the breaches were 2 to 4 mm deep. There were no
statistically significant differences in breach rate between the two
groups. Conclusions: The accuracy of insertion of pedicle screws in
the thoracic spine using computer-assisted navigation is equivalent
to that achieved using fluoroscopic guidance. Computer-assisted
navigation improves the safety of the surgical team during the pro-
cedure due to the absence of exposure to radiation. Therefore, there
is a need for future randomized controlled trials to be conducted in
the clinical setting to evaluate other outcomes, including duration of
surgery and blood loss during the procedure. Level of evidence IV.