• Title of article

    Radon concentrations in dwellings of Baghdad city- Iraq

  • Author/Authors

    ali, kamal k. university of baghdad - college of science - department of geology, Iraq , mohammed, aamir a. ministry of environment - radiation protection center, Iraq , ahmad, thuraya m. ministry of environment - radiation protection center, Iraq , ibrahim, safaa k. ministry of environment - radiation protection center, Iraq

  • From page
    1246
  • To page
    1254
  • Abstract
    In this study, radon concentrations were measured in dwellings at specified locations in Baghdad city using ionization chamber radon monitor (ALPHA GUARD PQ2000 PRO). The measurements were carried out at different locations of these dwellings (living rooms, bed rooms, bath rooms, and kitchens). The results of the survey showed that the overall minimum, maximum average and mean average radon concentrations in dwellings were 5.77±0.73 Bq/m^3, 23.27±13.57 Bq/m^3, and 10.67±4.14 Bq/m^3 respectively. The lowest average radon was found in (Ameryia) city, while the highest average radon concentration was found in (Kadmiya) city. Also, the results showed that the highest average radon concentration was found in the kitchens, while the lowest average radon concentration was found in the living rooms. The maximum annual effective dose in dwelling in Baghdad city in current study is 0.59 mSv.
  • Keywords
    Radon , Baghdad , dwellings , effective dose
  • Journal title
    Iraqi Journal Of Science
  • Journal title
    Iraqi Journal Of Science
  • Record number

    2639379