Title of article
Effects of Positive Corona Discharge on PH Value of Tap and Distilled Waters in Liquid system
Author/Authors
Abbas, Qusay Adnan University of Baghdad - College of Science - Department of Physics, Iraq
From page
141
To page
144
Abstract
In this paper, the effect of positive corona discharge on the PH values of tap and distilled waters are studied in water liquid system. The photographs of the results show that the shape of water drop that formed in the end of capillary tube is extended into a cone as well as a blue glow appears at the end of capillary tube. The size of cone decreases with increases of applied voltage and because of the change distance between the liquid electrode and the surface of liquid, the cone diameter at the end of capillary tube oscillates with period approximately 1 Sec. In addition, the PH values of both tested waters are constant when the applied voltage is less than 5 KV, while when the exterinal applied voltage is equal to or greater than 5KV, the PH value of both water types are increases rapidly where the tap water shows increases rate larger than that for distilled water.
Keywords
Corona discharge , Liquid discharge , PH value , Tap water , Distilled water
Journal title
Al-Nahrain Journal Of Science
Journal title
Al-Nahrain Journal Of Science
Record number
2646267
Link To Document