• Title of article

    Assessment of Internal and External Surrogates for Lung Stereotactic Body Radiation Therapy

  • Author/Authors

    SAVANOVIC ، MILOVAN Faculty of Medicine - University of Paris-Saclay , Strbac ، Bojan Physics department - MATER Private Hospital , Jaros ، Drazan Center for Radiotherapy - Affidea , Cazic ، Dejan Center for Radiotherapy - Affidea , Kolarevic ، Goran Center for Radiotherapy - Affidea , Foulquier ، Jean-Noel Faculty of Medicine - University of Paris-Saclay

  • From page
    352
  • To page
    360
  • Abstract
    Introduction: In this study, we aimed to evaluate internal (lung, heart and diaphragm) and external (nine glass marbles) marker motion in correlation with lung tumor motion and determine potential surrogate for respiratory gating radiation therapy (RGRT) depending on tumor localization, upper lobe (UL) versus lower lobe (LL). Material and Methods: We included 58 patients (34 male and 24 female) with small lung cancer (≤ 5cm), who underwent stereotactic body radiation therapy (SBRT). All patients were scanned and contoured in all ten phases (Varian Eclipse 13.7) after four-dimensional computed tomography simulation (4D-CT). The motions of internal and external markers were analyzed and correlated with tumor motion. Pearson correlation coefficient (PCC) was used to evaluate the correlation between internal and external marker motion and tumor motion. Results: The median (range) values of tumor motion were 3.2 (0.6-11.0) and 8.6 (4.0-24.0) mm in the UL and LL, respectively. The median (range) values of organs motion and PCC comparing UL vs. LL were 2.0 (0.3-9.1) vs. 6.0 (2.8-13.9) mm and 0.46 (0.30-0.95) vs. 0.79 (0.50-0.94) for the lung, respectively, 11.9 (2.5- 16.3) vs. 12.5 (5.0-22.5) mm and 0.68 (0.11-0.93) vs. 0.89 (0.30-0.99) for the diaphragm, respectively, and 3.9 (2.5-6.3) vs. 7.6 (4.5-8.6) mm and 0.49 (0.20-0.70) vs. 0.59 (0.36-0.83) for the heart, respectively. The external marker motion and correlation coefficient for UL and LL were 2.5 (0.9-7.4) vs. 2.3 (1.0-5.9) mm and 0.54 (0.09-0.96) vs. 0.73 (0.27-0.94), respectively. Conclusion: Lung and diaphragm motion correlate better with tumor motion than the external marker. Diaphragm motion can be an excellent indicator for treatment based on RGRT.
  • Keywords
    Lung Cancer , Motion , Surrogate Marker , Four , Dimensional , Computed Tomography , Stereotactic Body , Radiotherapy
  • Journal title
    Iranian Journal of Medical Physics (IJMP)
  • Journal title
    Iranian Journal of Medical Physics (IJMP)
  • Record number

    2676609