Title of article
Management of a Migrating Feeding Tube
Author/Authors
Al-Hashami, Zamzam S. Sultan Qaboos University Hospital - Department of Medicine, Oman , Al-Naamani, Khalid Armed Forces Hospital - Department of Gastroenterology, Oman , Al-Kalbani, Abdullah Armed Forces Hospital - Department of Gastroenterology, Oman
From page
412
To page
413
Abstract
A 67-year-old male with dementia presented with a locally advanced inoperable obstructive gastric adenocarcinoma. A jejunostomy (JS) was perfomed to insert a jejunal feeding tube; however, it was pulled out one month later by the patient. In order to keep the JS tract accessible, a size 20 Fr Foley catheter was placed which included an inflatable balloon filled with 10 cc of water. Unfortunately, the Foley catheter slipped internally a few days later with no symptoms or signs of an intestinal obstruction.
Journal title
Sultan Qaboos University Medical Journal (SQUMJ)
Journal title
Sultan Qaboos University Medical Journal (SQUMJ)
Record number
2690860