• Title of article

    Determination of Trace Amount of Manganese‎ in Water Samples by Micro-funnel Magnetic Stirring-assisted Liquid Phase Microextraction Technique

  • Author/Authors

    Ramezani ، Majid Department of Chemistry - faculty of Science - Islamic Azad University, Arak Branch , Ghalenoei ، Maryam Department of Chemistry - faculty of Science - Islamic Azad University, Arak Branch

  • From page
    143
  • To page
    150
  • Abstract
    In this study, trace amounts of manganese ions were extracted using a sensitive, selective, rapid, and simple micro-funnel magnetic stirring-assisted liquid phase microextraction (MF-MSA-LPME) method and determined by flame atomic absorption spectrometry (FAAS). 1-(2-Thiazolylazo)-2-naphthol) (TAN) and 1-octanol were chosen as chelating agent and extraction solvent, respectively. The effective parameters on extraction efficiency such as type and volume of extraction solvent, pH of sample solution, ligand concentration, extraction time, and ion strength were investigated and optimized. Under the optimum form, limit of detection (LOD), relative standard deviation, and the enrichment factor were 0.16 μg L^-1, 2.9%, and 252, respectively. The calibration graph was linear over the range of 1-120 μg L^-1 with correlation of coefficient r² = 0.995.The proposed method could successfully determine trace amounts of manganese ions in the real water samples with good accuracy and validity.
  • Keywords
    Micro , funnel magnetic stirring , assisted liquid phase Microextraction , Manganese , Flame atomic absorption spectrometry , Water samples
  • Journal title
    Journal of Chemical Health Risks
  • Journal title
    Journal of Chemical Health Risks
  • Record number

    2712546