Title of article
Effect of Liquid Inhibitor De-dio^TM on Dioxin-Furan Emission from Medical Waste Incineration Plant
Author/Authors
Rashid, M. Malaysia-Japan International Institute of Technology - Air Resources Research Laboratory, Malaysia , Ramli, M. Universiti Teknologi Malaysia - Faculty of Chemical Engineering, Malaysia , Ammar, M. AMR Environmental Sdn Bhd, Taman Sri Pulai Perdana, Malaysia , Noorhafizah, K. AMR Environmental Sdn Bhd, Taman Sri Pulai Perdana, Malaysia
From page
47
To page
51
Abstract
The aim of the study was to investigate the effects of liquid inhibitor (known as De-dio^TM) on the emission of dioxin-furan from medical waste incineration plants. Various concentrations of De-dio^TM solutions were tested on the medical waste incinerator combustion chamber with an injection flow rate of 1.5 L/min. The sampling protocol of US EPA Method 23 was adopted to collect the sample using a modified US EPA Method 5 sampling train. The flue gas emission was collected before and during the injection of the chemical. The result showed that the De-dio^TM was able to reduce or minimize the formation of dioxinfuran to meet its regulatory limits. The study illustrates that the higher the concentration of De-dio^TM solution, the lower the dioxin-furan emission was observed in the flue gas.
Keywords
Inhibitors , dioxin , furan , incineration , medical waste