• Title of article

    Inter and Intra-rater Reliability of Lateral Cephalometric Analysis Using 2D Dolphin Imaging Software

  • Author/Authors

    Khosravani, Sarvin Undergraduate Student - School of Dentistry - Shahid Beheshti University of Medical Sciences - Tehran, Iran , Esmaeili, Saharnaz Undergraduate Student - School of Dentistry - Shahid Beheshti University of Medical Sciences - Tehran, Iran , Malek Mohammadi, Nazanin Undergraduate Student - School of Dentistry - Shahid Beheshti University of Medical Sciences - Tehran, Iran , Eslamian, Ladan Dept. of Orthodontics - School of Dentistry - Shahid Beheshti University of Medical Sciences - Tehran, Iran , Dalaie, Kazem Dept. of Orthodontics - School of Dentistry - Shahid Beheshti University of Medical Sciences - Tehran, Iran , Motamedian, Saeed Reza Dept. of Orthodontics - School of Dentistry & Dentofacial Deformities Research Center - Research Institute of Dental Sciences - Shahid Beheshti University of Medical Sciences - Tehran, Iran

  • Pages
    5
  • From page
    148
  • To page
    152
  • Abstract
    Cephalometric radiographs are widely used in diagnosis and treatment planning. In the past, these radiographs used to be analyzed manually, but nowadays due to the possibility of errors and time-consuming nature of manual tracing, digital methods are replacing the manual methods. The reliability of computer-assisted analysis is of great importance. The purpose of this study was to investigate the inter and intra-rater reliability of 2D Dolphin imaging software version 10.0.00.53. Methods To assess the intra-rater reliability of lateral cephalometric analysis, 25 lateral cephalograms traced by one operator using Dolphin imaging software were traced again by the same examiner 2 weeks later. To assess the inter-rater reliability, 25 lateral cephalograms were traced independently by two examiners. Overall, 80 measurements including 43 linear, 34 angular, and 3 ratio measurements were made. The interclass correlation coefficient (ICC) was calculated to assess the inter-rater and intra-rater reliability. ICCs above 0.75 were considered good. Results The ICC for intra-rater reliability was above 0.75 for all parameters except lower vertical height depth ratio (ICC=0.51), inter-labial gap (ICC=0.54), superior sulcus depth (ICC=0.67), articular angle (ICC=0.733), and ramus height (ICC=0.728). The ICC for inter-rater reliability was above 0.75 for all parameters except nose prominence (ICC=0.73). Conclusion Dolphin imaging software showed good intra-rater reliability for most parameters and good inter-rater reliability for almost all parameters.
  • Keywords
    Digital Technology , Reproducibility of Results , Orthodontics , Cephalometry
  • Journal title
    Journal of Dental School
  • Serial Year
    2020
  • Record number

    2717602