Title of article
On the Optimization of the Protocol for Automated Radiosyntheses of [68Ga]Ga-Pentixafor, [68Ga]Ga-FAPI-4 and [68Ga]Ga-DOTATATE in a Modular-Lab Standard
Author/Authors
Menon ، Sreeja Health Physics Division - Bhabha Atomic Research Centre , Mitra ، Arpit Radiopharmaceutical Laboratory - Board of Radiation and Isotope Technology , Sahu ، Sudeep Radiation Medicine Centre - Bhabha Atomic Research Centre , Lad ، Sangita Radiation Medicine Centre - Bhabha Atomic Research Centre , Chakraborty ، Avik Homi Bhabha National Institute , Ray ، Mukti Homi Bhabha National Institute , Banerjee ، Sharmila Homi Bhabha National Institute
From page
149
To page
160
Abstract
Objective: The present work describes the automated radiochemical syntheses of different PET tracers like [68Ga]Ga-Pentixafor, [68Ga]Ga-FAPI-4 and [68Ga]Ga-DOTATATE using optimized single protocol in the non-cassette based Eckert Ziegler (EZ) Modular Lab (fixed tubing system) without any modification in the inbuilt human machine interface (HMI) software. Recently, PET agents viz. [68Ga]Ga-Pentixafor and [68Ga]Ga-FAPI-4 are gaining prominence for the diagnosis of overexpressed Chemokine Receptor-4 (CXCR4) and Fibroblast Activation Protein (FAP) receptor, respectively, in the microenvironment of numerous cancer types. The promising results observed with the clinical usage of [68Ga]Ga-DOTATATE produced using the automated protocol, provided impetus for the clinical translation of [68Ga]Ga-Pentixafor and [68Ga]Ga-FAPI-4 using the in-house developed automated radiolabeling protocol.Methods: Herein we report a single radiolabeling protocol for the automated preparation of [68Ga]Ga-Pentixafor and [68Ga]Ga-FAPI-4 in the non-cassette based EZ Modular-Lab Standard radiochemistry module, without any changes in schematic, graphical user interface (GUI) software and time list, from that used for routine production of [68Ga]Ga-DOTATATE in our centre, since 2015. Physico-chemical quality control and in-vitro stability analyses were carried out using radio-TLC and radio-HPLC.Results: The automated protocol yielded reliable and consistent non-decay corrected (ndc) radiochemical yield (RCY) of (84.4±0.9)% and (85.5±1.4)% respectively, for [68Ga]Ga-Pentixafor and [68Ga]Ga-FAPI-4, with RCP 98%, which are comparable to the RCY of (84.4±1.2)% and RCP (99.1±0.3)% for [68Ga]Ga-DOTATATE. The biological quality control studies confirmed the formulations to be of ready-to-use pharmaceutical grade.Conclusion: The consistent and reliable RCY and RCP of multiple 68Ga-labeled PET tracers by single optimized automated radiochemistry protocol exhibits the versatility of the EZ Modular Lab.
Keywords
[68Ga]Ga , Pentixafor , [68Ga]Ga , FAPI , 4 , [68Ga]Ga , DOTATATE , Modular , Lab Standard , PET , CTA
Journal title
Asia Oceania Journal of Nuclear Medicine and Biology
Journal title
Asia Oceania Journal of Nuclear Medicine and Biology
Record number
2763981
Link To Document