Title of article
Comparison Static and Dynamic Ultrasound Techniques of DDH: The Role of the Patient’s Position
Author/Authors
Yousefi ، Mohammad Reza Department of radiology - faculty medicine - University of medical science University of medical science , Yazdanparast ، Mojgan Department of radiology - faculty medicine - University of medical science University of medical science , Neshati ، Hashem Department of radiology - faculty medicine - University of medical science University of medical science , Abdi ، Reza Department of Pediatric Orthopedic Surgery - University of Medical Science , Hasanian ، Mohammad Department of Radiology - faculty medicine - University of Medical Sciences , Alamdaran ، Seyed Ali Department of radiology - faculty medicine - University of medical science
From page
191
To page
197
Abstract
Objectives: The ultrasound examination of the hip joint is performed in the static (Graf) technique in the lateral recumbent position and in the dynamic technique in the supine position. This study compares the two static and dynamic techniques and assesses the role of the patient’s position in the examination of DDH.Methods: This cross-sectional study was conducted in 2020-2021 at Akbar Hospital, Mashhad University of Medical Sciences, Iran. 126 patients suspected of having DDH (199 hip) infants were enrolled in the study. All ultrasound examinations were performed with two static and dynamic techniques by a pediatric radiologist.Results: In the static and dynamic ultrasound examinations, the average alpha angle was 51.57 ± 6.41 degrees, and 53.41 ± 6.94 degrees, respectively. These changes were not statistically significant (P = 0.312). The relationship and agreement between instability with dynamic technique and instability with static technique (IIC unstable, D, III, and IV) were investigated. Significant agreement (Kappa=0.77 (95% CI: 0.66-0.87) with excellent clinical significance was obtained between the two ultrasound examination method. Also, in terms of DDH types in the static method with instability types in the dynamic method, a substantial agreement was found between the two examination methods (Kappa =0.67; (95% CI: 0.59-0.75) with good clinical significance.Conclusion: In the ultrasound examination of DDH with static and dynamic techniques, the change in the alpha angle was not statistically significant. Therefore, the hand of the radiologist is open in measuring alpha angles and there is no need to emphasize a specific position. The type of DDH in the static technique completely corresponded to the type of stability or instability in the dynamic technique. Level of evidence: IV
Keywords
Developmental Dysplasia of the Hip (DDH) , Dynamic Technique , Hip Ultrasound Angles , Static (Graf) Technique
Journal title
The Archives of Bone and Joint Surgery
Journal title
The Archives of Bone and Joint Surgery
Record number
2765179
Link To Document