• Title of article

    Chronic Dose Due to a Continuous Tritium Release Calculated by CAP88-PC and NORMTRI

  • Author/Authors

    Overcamp، Thomas J. نويسنده , , Imboden، Stacey F. نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    -113
  • From page
    114
  • To page
    0
  • Abstract
    CAP88-PC, Version 2.0, and NORMTRI, which are based on the Gaussian plume model, were used to estimate the chronic dose due to a continuous, ground-level, atmospheric release of tritium as tritiated water. For the same conditions the predictions of CAP88-PC were found to be higher by a factor of 3 or less than those of NORMTRI. The major differences are due to the use of higher dose coefficients in CAP88-PC and NORMTRIʹs method of calculating the tritium content of food.
  • Keywords
    high-angle annular detector dark-field scanning transmission electron microscopy , long period stacking order , magnesium-cupper-yttrium , precipitate , amorphous , high-resolution transmission electron microscopy
  • Journal title
    NUCLEAR TECHNOLOGY
  • Serial Year
    2006
  • Journal title
    NUCLEAR TECHNOLOGY
  • Record number

    30093