Abstract
It is important for laser designers to study the characteristics of heat transfer from the laser crystal slab to the coolant in high-power DPSS laser operations. We have simulated and obtained the optimum heat transfer coefficient and coolant flow rate for our cavity design, in which the circulating coolant is maintained at a constant temperature. It has been determined that the coolant temperature and the convective heat transfer coefficient (h) are important parameters in the thermal analysis. The coefficient h is affected by the coolant flow rate, the physical properties of the laser slab and the coolant and the pumping cavity geometry. Using analytical heat transfer equation, for cooling water temperature of 300 K, the optimum flow rate for our cavity geometry is found to be 390 cm3/s, corresponding to h=5 W/cm2 K.
Keywords
Pulsed Nd:YAG laser , Laser power density control , discharge circuit , Successive charge